1. Type and nature of materials; type and nature of agentia; dosage; dosing concentration. Or contact engineer of Longqiao to help you. Special specification can be customized.
2. Inlet water pressure should be more than 0.25Mpa.
3. Dosing pump can be screw or dosing pump.
4. Preparative capacity is in the table of specifications and parameters the data of polymer which is cured for 0.5h
Parameter Type | PT430 | PT958 | PT1340 | PT2660 | PT4165 | PT6660 | |
Maxium preparative capacity(l/h) | 430 | 958 | 1340 | 2660 | 4165 | 6660 | |
Tank capacity(l) | 650 | 1600 | 2100 | 3000 | 4200 | 6700 | |
inflow(kW) | 750 | 1200 | 1800 | 2400 | 3000 | 4000 | |
Power of dry powder machine(kW) | 0.18 | 0.18 | 0.18 | 0.18 | 0.18 | 0.18 | |
Power of mixer(kW) | 0.55 | 2*0.55 | 2*0.75 | 2*1.0 | 2*1.5 | 2*2.2 | |
Powder hopper capacity(l) | 60 (optional:100,160,200 for selection) | ||||||
Size (mm) | L | 1304 | 1650 | 1650 | 1650 | 2340 | 3440 |
W | 734 | 1320 | 1320 | 1320 | 1320 | 1320 | |
H | 970 | 970 | 1230 | 1650 | 1650 | 1650 | |
Water inlet | DN20 | DN25 | DN32 | DN40 | DN40 | DN50 | |
Vent nozzle | DN20 | DN25 | DN25 | DN40 | DN40 | DN50 | |
Overflow port | DN32 | DN40 | DN40 | DN50 | DN50 | DN50 | |
Agentia discharge port | DN20 | DN25 | DN25 | DN40 | DN40 | DN50 |